Size: 18.5" (47.1 cm) wide × 21.5" (54.6cm) deep × 11" (27.9 cm) high
Cabinet: 17"(43.2cm) wide × 20.8" (52.3cm) deep × 1.25"(26cm) high
Net weight: 145 pounds (65.9 kg)
Front Panel Material: Steel with polyester overlay
Case material: Steel
- RF80-K PC Interface with ABMS-8 Battery Management System
- Simple, Straight-Forward Operation
- Heavy Duty Design and Performance
- Digital Timers & Displays
- Charges and Analyzes All Aircraft Batteries Ni-Cd and Lead-Acid
- Unique ReFLEX Quick-Charger
- Constant Current Charge
- 2-Step Constant Current Charge
- Constant Potential Charge
- Constant Current Discharge
- DigiFLEX Analysis for Visual Status Indication
- Cell Voltage Balance Testing
- Internal Voltmeter CE European Approval RF80-K (CE)
Note: The RF80-K model replaces the previous RF80H design, which was discontinued in 1991.
Mechanical
Electrical - Input
Voltage: 110, 208, 220 VAC
Frequency: 50/60 Hz
Current: 25 amperes, maximum
Electrical - Output
Unique RF80-K ReFLEX Charge: 2 to 80A
Constant Current Charge: 1 to 65A
Constant Current Discharge: 0.2 to 60A
Electrical - Displays
Current: 99.9 full scale, accuracy ±2% of full scale
Individual Cell: 19.9 full scale, accuracy ±2% of full scale
DigiFLEX: 10 segment trend bar display
Environmental
Non-Operating:
Ambient Temperature: -40°C to +71°C
Altitude: 0 to 50,000 feet
Operating:
Ambient temperature: 0 °C to 50 °C
Altitude 0 to 8,000 feet
Controls and Indicators
Controls:
ON/OFF
Charge Timer
Discharge Timer
Cycle Reset
Operating Mode
Charge Method - No. of Cells
Discharge Cycle
A/B Switch
Indicators:
GREEN - Battery acceptable, GO
RED - Battery reject, NO-GO
YELLOW - Negative Slope, Possible hot battery