Size: 8" (20.3cm) wide × 9" (22.9 cm) deep × 4.3 " (10.8 cm) high
- PC Interface for use with ABMS-4 Battery Management System Software
- Compatible with RF80-K, RF80-M and U-60 charger/analyzers
- Designed for nickel-cadmium and lead-acid batteries
- Automatically scans nickel-cadmium batteries, acquiring real-time cell data
- Display shows all cell voltages, battery current/voltage, and faults
- Cells with faults flash on/off
- Print button to print out display at any time or reprint last report
- Documents initial, intermediate, and ending voltages for every cell
- Documents elapsed charge or discharge time, and ampere-hours
- Documents charge or discharge history at regular intervals
- Graphs battery voltage for charge/discharge Visual and audible warnings for fault conditions
- Quick-connect cell probes and wiring harness support arm for easy use
- Mounts on or under shop shelf
Mechanical
Electrical - Input
Input Power 90 to 135 or 200-265 VAC
Frequency: 50 to 60 Hertz
Current Requirements: 0.03A, typical
Power Switch: Opens both sides of line
Electrical - Output
Serial Printer Output: Epson Format (must use serial printer kit)
Serial Printer Kit 115v p/n 121470-001
Serial Printer Kit 230v p/n 121470-002
Computer Output: RS232 serial, proprietary interface (use ABMS-4 Battery Management Software)
Electrical - Displays
Environmental
Non-Operating:
Altitude: 0 to 40,000 feet
Temperature: -20 to +75 degrees C
Relative Humidity: 60% maximum
Operating:
Altitude: 0 to 8,000 feet
Temperature: 0 to +50 degrees C
Relative Humidity: 95% maximum
Controls and Indicators
Power ON/OFF
Clear Key
Reset Key
Mute Switch